Medical Thermoplastic Splinting Material for Orthopaedics Problems or Rheumatology Disorders

Product Details
Customization: Available
Type: Rehabilitation Material
Material: Plastic
Still deciding? Get samples of US$ 38/piece
Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 RMB
Plant Area
1001~2000 square meters
  • Medical Thermoplastic Splinting Material for Orthopaedics Problems or Rheumatology Disorders
  • Medical Thermoplastic Splinting Material for Orthopaedics Problems or Rheumatology Disorders
  • Medical Thermoplastic Splinting Material for Orthopaedics Problems or Rheumatology Disorders
  • Medical Thermoplastic Splinting Material for Orthopaedics Problems or Rheumatology Disorders
  • Medical Thermoplastic Splinting Material for Orthopaedics Problems or Rheumatology Disorders
  • Medical Thermoplastic Splinting Material for Orthopaedics Problems or Rheumatology Disorders
Find Similar Products

Basic Info.

Model NO.
AJY-KB-PINK
Ethylene Oxide Sterilization
High-Temperature Sterilization
Quality Guarantee Period
Two Years
Group
People in Any Ages
Logo Printing
Without Logo Printing
Transport Package
Carton Box
Specification
600*900mm
Trademark
Aojianyi
Origin
China
HS Code
3920109090
Production Capacity
10000

Product Description

Medical Thermoplastic Splinting Material for Orthopaedics Problems or Rheumatology Disorders

Name: thermoplastic splinting material (LTTP)
Size: 600*900mm
Perforation: 0%, 5%, 10%, 19%, 22%, customized 
Color: white, pink, green, blue, orange, original, rose
Usage: Immobilization & sterilization
Applicaton: Orthopedic / rehabilitation
Users: OT/ PT
Certification: CE, SGS


Medical Thermoplastic Splinting Material for Orthopaedics Problems or Rheumatology Disorders

Medical Thermoplastic Splinting Material for Orthopaedics Problems or Rheumatology DisordersMedical Thermoplastic Splinting Material for Orthopaedics Problems or Rheumatology DisordersMedical Thermoplastic Splinting Material for Orthopaedics Problems or Rheumatology DisordersMedical Thermoplastic Splinting Material for Orthopaedics Problems or Rheumatology DisordersMedical Thermoplastic Splinting Material for Orthopaedics Problems or Rheumatology DisordersMedical Thermoplastic Splinting Material for Orthopaedics Problems or Rheumatology Disorders


Description:

Thermoplastic sheets offer the ideal solution. These sheets are widely used to make custom splints and braces that partially or totally immobilize a body part. 
 Custom-fitted splints and braces are formed from thin, flat, thermoplastic sheets. Once heated in hot water, these sheets become soft and pliable. Then, they are trimmed and molded to any part of the body for a perfect custom fit. Hook and loop straps hold the splint in place.

Application Field:
  1. Orthopedics
  2. Rehabilitation hospital
  3. Burn department
  4. Aesthetic and Reconstructive Plastic Surgery
  5. ENT department
  6. First Aid & Emergency
How to use it?
  1. Adjust the water bath to 75ºC, put the sheet into hot water for 2-3 minutes.
  2. After the sheet turns soft and pliable, put it on a soft cloth and dry it on.
  3. Mold it is according to the body part, hoop, and loop straps behold the splint in place, padding/liner material increase patient comfort.
  4. Keep the sheet for 10 minutes, it can be plastic well.
  5. With a perfect memory, it can be remold more than 8 times.
Attention:
1. Adjust the water temperature to 65ºC-75 ºC, don't be more than 80 ºC, if more than 80 ºC, it will make the splint contraction and deformation.
2. Be sure not to place the sheet in hot water for too long a time. In general, 2-3 minutes should be enough to make it soften and activate.
3. Working surroundings. When the operation room temperature is more than 20ºC, it can be plastic within 1.5-3 minutes; When the room temperature drops to 10ºC, the plastic time is about 30-50 minutes.
4. For orthopedic splints, after activation, it can be stretched to 1.5 times as its original size. Excessive pulling could affect its reshaped resilience and damage its memory function.
5. How to restore a molding splint back to its factory settings? Just put it into the hot water with 65ºC-75 ºC, and then it will rebound automatically after 5 minutes.
6. Due to the characteristics of the material itself, in the activation process, it will occasionally occur small area of sticky. Please be sure not to pull randomly. When it leaves the water to solidify, it will automatically relieve adhesion.
7. Storage in room temperature is enough.
8. The product is Eco-friendly, put it outside in the yard with a natural climate for about 12 months, it will be degraded by itself.

Cases
Medical Thermoplastic Splinting Material for Orthopaedics Problems or Rheumatology DisordersMedical Thermoplastic Splinting Material for Orthopaedics Problems or Rheumatology Disorders

Group Union

Medical Thermoplastic Splinting Material for Orthopaedics Problems or Rheumatology Disorders
Medical Fair

Medical Thermoplastic Splinting Material for Orthopaedics Problems or Rheumatology DisordersMedical Thermoplastic Splinting Material for Orthopaedics Problems or Rheumatology Disorders

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier